This plant is a waste transfer station that bales waste before it is shipped out of the factory. Simdean were asked to design a system that would remove the odour from the extraction gases coming from the waste transfer building.
The overall system was designed by Simdean for a volume flow rate of 60,000 m3/h that could, if required, be increased to a maximum of 75,000 m3/h.
The client supplied a reverse jet cartridge filter, carbon adsorber vessels to Simdean’s design, a control panel to Simdean’s design and an installation team supervised by Simdean personnel.
All other aspects of the project were supplied by Simdean:
The exhaust stack from the system’s two adsorbers had to be single, unsupported and 19m high. Simdean designed both the stack itself and the structural work needed for its foundations.
After installation by the client (under instruction from ourselves) we undertook the commissioning of the plant.